Researchers have demonstrated that digital light processing 3D printing can fabricate prototype microfluidic devices with higher dimensional precision and in substantially less time than conventional computer numerical control micro-milling. In a comparative evaluation of manufacturing approaches for microscale fluidic systems, a digital light processing printer produced a disk sector prototype in less than five minutes, whereas machining a comparable component using a micro-milling machine required five and a half hours. The investigation evaluated how production duration, financial cost, and structural accuracy compare across both fabrication routes.
Microfluidic technology manipulates fluids at the micro-scale and nano-liter level and is utilized across engineering, biology, biomedical research, and medical treatments. Conventional microfluidic chips are commonly produced from silicon, glass, or elastomeric materials containing micron-scale channels through which fluids travel. While stereolithography has been widely investigated for microfluidic applications by curing photopolymer resin layer by layer, uncured materials can pose toxicity concerns that compromise biocompatibility, and developing non-toxic alternatives often involves extensive, costly experimentation.
To address these processing challenges, the research team designed a disk sector containing microscale channels and pillars using AutoCAD software. The design featured a sector measuring 5 millimeters in thickness and 6 centimeters in diameter, incorporating microchannels planned at widths of 100 micrometers and 200 micrometers. The authors focused the design on a single sector of a complete disk specifically to evaluate a prototype device without conducting live biomedical assays during the initial fabrication phase.
For the additive manufacturing process, the team utilized a commercial Parsa 3D digital light processing printer operating with a specified accuracy of 50 micrometers. Digital light processing operates by projecting light across an entire layer simultaneously to solidify photopolymer resin, building three-dimensional geometries layer by layer. The manufacturing workflow divided the channel construction systematically across bottom, channel, and roof layers, allowing localized regulation of the photopolymerization step to avoid resin overdosing inside the channel voids.
The additive builds employed BioMed Clear Resin class VI, a rigid, transparent photopolymer formulated for biocompatible applications requiring long-term contact with skin or mucosal tissue. This material grade is intended for wear resistance, low water absorption, and use in drug delivery and pharmaceutical systems. Following printing, parts underwent post-processing by washing in isopropyl alcohol to eliminate uncured resin, air-drying, and curing under an ultraviolet light source in accordance with manufacturer-specified time and temperature guidelines.
For comparison, a subtractive prototype was manufactured on a DAHLIH-MCV 1200 computer numerical control machine using poly-methyl methacrylate, commonly known as Plexiglass. While computer numerical control micro-milling is widely used for creating micro-features in rigid substrates and specialized alloys such as Ti6Al4V titanium, the microstructure of the workpiece strongly influences machining outcomes. The investigators noted that the micro-milling process produced unsatisfactory optical clarity and curvature on the sector workpiece, even though its outer surface finish showed an aesthetically clean appearance.
Scanning electron microscopy revealed marked differences in channel geometry between the two fabrication methods. Channels manufactured with digital light processing exhibited an average width of 95 micrometers and an average depth of 191 micrometers, reflecting an error margin of 5 to 9 micrometers relative to the AutoCAD design specifications. In contrast, the micro-milled channels exhibited an average width of 330 micrometers and an average depth of 280 micrometers, indicating substantially larger dimensional deviations attributed to machining or measurement errors.
The study also analyzed surface properties, recording a surface roughness of 0.1 micrometers on the resin devices fabricated by digital light processing. Surface roughness within microchannels directly influences internal fluid behavior, as elevated roughness increases frictional resistance and induces turbulence, which drives up pressure drops.
Economic and throughput metrics similarly favored the additive technique for small-batch prototyping. In addition to reducing manufacturing time from 5.5 hours down to under 5 minutes per unit, the unit cost of the digital light processing prototype was substantially lower than chips produced by micro-milling. Consequently, digital light processing was identified as a rapid, inexpensive, and accurate fabrication alternative for producing limited numbers of microfluidic devices.
The researchers outlined several explicit experimental boundaries that remain to be addressed in future work. The prototype device was not tested in active biomedical applications such as organ-on-a-chip models, point-of-care diagnostics, or disease simulations. Furthermore, standard regulatory biocompatibility assessments, including cytotoxicity, irritation, and sensitization evaluations, were not performed, and the microchannels were not evaluated using computational fluid dynamics simulations or experimental fluid flow measurements.
Earlier investigations into additive microfabrication explored several distinct technical routes to construct fluidic conduits capable of mimicking anatomical structures in organ-on-a-chip platforms. Across the broader additive landscape, researchers evaluated modalities such as fused deposition modeling, selective laser sintering, stereolithography, and inkjet printing to generate microscale channel architectures without specialized tooling. Desktop fused deposition modeling was likewise examined by Rehmani and associates to fabricate experimental microchannels, while Jin and colleagues developed an inexpensive, time-efficient approach utilizing direct ink writing.
The operational success of photopolymerization systems depends on material composition, which directly influences resin printability, layer resolution, and finished mechanical integrity. Beyond standard medical-grade polymers, formulations such as Clear V4 resin serve as recognized benchmarks within microfluidics research, selected for their demonstrated biocompatibility, reliable standard printing behavior, and enhanced optical clarity.
Achieving precise channel wall definitions required experimental optimization of printing machine parameters, focusing specifically on the interplay between printing pressure and printing speed. By systematically evaluating how these dynamic mechanical settings affected wall geometry, the researchers developed an optimized printing prototype.
Subject of Research: Comparative fabrication of prototype microfluidic devices using digital light processing 3D printing and micro-milling
Article Title: Manufacturing of Microfluidic Device Using 3D-Printing Method for Biomedical Applications
Article References: Taati, F., Navidbakhsh, M., & Hassani, K. (2026). Manufacturing of Microfluidic Device Using 3D-Printing Method for Biomedical Applications. Biomedical Materials & Devices, 4(2), 2207-2212. https://doi.org/10.1007/s44174-025-00351-z
Image Credits: AI Generated
DOI: 10.1007/s44174-025-00351-z
Keywords: 3D printing, digital light processing, microfluidics, micro-milling, BioMed Clear Resin, biocompatible materials, computer numerical control, poly-methyl methacrylate, scanning electron microscopy, dimensional accuracy, surface roughness, rapid prototyping, photopolymer resin, channel fabrication, microfabrication
Tags: 3D printingBiocompatible materialsBioMed Clear Resinchannel fabricationcomputer numerical controldigital light processingdimensional accuracymicro-millingmicrofabricationmicrofluidicsphotopolymer resinpoly methyl methacrylaterapid prototypingscanning electron microscopysurface roughness